Dukers - Change Fan Control Settings on Dixell Controller (Refrigerator & Coolers) [How-To]
Описание
Today we will be learning to change the Fan Control Settings on the Dixell Digital Controller installed on your Dukers Appliance Refrigerator or Cooler. Changing the "FC" setting will either allow you to keep the evaporator fan running or both evaporator and condenser fan to be kept on simultaneously even during defrost. However today we will be taking a look specifically at the "OY" which will only keep your evaporator fan running.
1. To access the main frame by holding down the two bottom buttons, labeled "SET" (on the right) and " AUX/ down arrow" (on the left)
2. If properly engaged the monitor will read "nP". Do not let go until the monitor reads "HY". Once you release the monitor will read "LS"
3. On the main frame you will hit the "up arrow" key until you the monitor reads "FC"
4. Hit "SET" and the monitor should be reading "CY"
5. Hit the "up arrow" key once and the monitor will read "OY"
6. Hit "SET" and the monitor will flash and be back at the main frame
7. Let the monitor sit and it will return to the temperature reading.
You have successfully set your units evaporator fan to be constantly running.