Описание

Version with Audio coming soon, but the kids are asleep.

We had a power outage that took 36 of our 3TB nearline SAS drives offline in a way that our LSI 9286CV-8eCC lost its mind (and configuration). It thought all of our previously configured drives were now "unconfigured bad", so I logged into the LSI MegaRAID Storage Manager and simply switched those drives to "Unconfigured Good" and they all indicated they had a foreign config. Once they were all "Unconfigured Good" I was able to scan foreign config, import all configs, apply the config, and test and view all of my data!