The Evosta 2 LED can show error codes.
2 Flashes – Trip
Engine control loss, could be caused by wrong parameters, rotor blocked, disconnected phase, disconnected engine. Check if the rotor can rotate freely, deblock manually if necessary.
3 Flashes – Short circuit
Short circuit on phases or between phase and earth. Power down, wait 30 seconds and power the circulator.
4 Flashes – Overrun
Software failure. Power down, wait 30 seconds and power the circulator.
5 Flashes – Safety
Module error, could be caused by an unexpected over current or other hardware fault of the electronic board. Wait for 30 minutes without switching off the circulator.