In this video, we address several common issues experienced with the RCD360Pro3 Navigation System, including the display of the error code “dra7xx-g5-r1 login,” Bluetooth calling malfunctions, and shutdown issues due to operating outside the recommended temperature range 【{outside of operating temperature range.switching screen off }】.

Follow these steps for troubleshooting:

1.Turn off the device and disconnect it from the power source.
2.Remove the 4 screws securing the radio casing.
3.Carefully detach and reattach the screen from the main unit.
4.If dust entered during installation, use a clean brush, similar to a toothbrush, to clean the connectors before reassembly. This step helps resolve issues related to the "outside of operating temperature range.switching screen off" error and potential Bluetooth call problems.
Securely fasten the screws on the back of the radio to ensure a stable connection.
5.Power on the device again to check if the issue is resolved.